iCT / Integral Clinical Trial

Earlier detection.
Less avoidable rework.

iCT is being developed to check source-linked clinical trial events against protocol requirements, identify potential execution gaps, and provide traceable evidence for timely human investigation.

Current stage: product development, documented requirements and demonstration prototypes
The core idea

Oversight without
the information overload.

Three essential capabilities—with technical explanation available on demand.

PROTOCOL

Check the sequence.

Compare recorded activities with the study's applicable timing, order and completeness requirements.

Rule configuration

The intended rule model uses explicitly configured, version-controlled rules mapped to approved protocol amendments. Checks can assess visit windows, prerequisite sequences and completeness of expected evidence.

Each evaluated rule needs an explicit link to the applicable protocol or amendment context and effective period. The current development approach relies on configured rules; automatic rule extraction from protocol text is a separate research and development topic.

EVIDENCE

Keep the provenance.

Link findings to their originating event, source system and timestamp.

Provenance and timing

The proposed evidence model includes source references, identities or authorized role context, normalized timestamps, event sequence and integrity metadata. It must distinguish the timestamp reported by a source from the time an event was received or processed.

DLT-based integrity anchoring is part of the prototype direction and may support tamper-evident metadata. Source accuracy, clinical interpretation and validation of connected systems remain subject to their own evidence and controls.

REVIEW

Focus human attention.

Show potential deviations and supporting context to the authorized people who can assess them.

Human review and evaluation

Proposed views include monitor worklists, sponsor oversight metrics and controlled read-only inspection access. Alerts are candidates for review, not automatic determinations of protocol noncompliance.

Planned functionality includes configured reminders before protocol-defined procedure deadlines. Pilot evaluation should assess whether earlier detection and intervention reduce avoidable rework, operational costs and delays against a defined baseline. It should also measure missed events, false positives, usability, data availability and the time from source event to actionable finding.

The professional reviewer remains accountable for assessment, escalation and documented disposition; the system does not independently determine clinical significance.

Planned extension — not yet implemented

AI-assisted resolution guidance

After a deterministic check identifies a potential deviation, a proposed AI component would retrieve the applicable versions of protocols, SOPs and other controlled requirements, cite verifiable clauses and source evidence, and suggest an assessment, action and escalation roadmap. Authorized professionals would review, accept, modify or reject its suggestions. This capability remains planned and subject to development, testing and validation.

Conceptual architecture

An oversight layer
across study systems.

Source data remains in the appropriate operational systems; iCT focuses on checks and traceable evidence.

Illustrative future-state architecture. Real integrations, roles and data flows depend on system permissions, study configuration and validation scope.

Interfaces, security and validation

Interoperability

Candidate interfaces include HL7 FHIR and CDISC ODM where appropriate, plus vendor-specific APIs for CTMS, eTMF and RTSM. Access rights, data-field semantics, mapping versions, event ordering and source-system provenance require assessment before integration.

Security and data protection

The architecture is designed around enterprise SAML/OIDC role integration, encryption, key management and read-only source access to support customer security reviews. Deployment-specific controls require verification for the intended use.

System qualification

iCT's SRS package and prototypes provide development evidence. Production use would still require defined intended use, risk assessment, configured interfaces and protocol rules, qualification/validation activities and operating procedures tailored to the deployment.

Illustrative use case

A missing
visit reading.

Expected activity

The protocol requires a specified measurement within the visit window.

Recorded evidence

Events and timestamps are received from an authorized study source.

Candidate finding

iCT would flag a missing or late event and show the underlying references for review.

For this scenario, a configured rule would need a subject or visit reference, the applicable protocol version, an expected time window, a qualified event source and an explicit policy for incomplete, delayed or corrected data. Where source data is missing or unavailable, the correct result may be an unresolved evidence gap rather than a confirmed protocol deviation.

Further reading

Explore the iCT case.

Explore concise product information and discuss available technical materials for a focused iCT evaluation.

Investment

iCT opportunity

Product rationale, current stage and milestones, with sensitive details withheld.

Investment overview
Pilot discussion

Explore a focused iCT use case.

We can discuss specific protocol checks, available source evidence and evaluation criteria.

Contact Integretix